Model/Brand/Package
Category/Description
Inventory
Price
Data
-
Category: transformerDescription: CURR SENSE XFMR 150A48341+$158.900110+$154.754950+$151.5769100+$150.4715200+$149.6424500+$148.53711000+$147.84622000+$147.1553
-
Category: transformerDescription: 230V Communication primary VC/VCM series single or double secondary windings, used for series or parallel connection of vacuum epoxy resin molding, compliant with UL94V-O low winding capacitance low radiation noise 100% electrical and insulation test additional fixing points to ensure board installation fastening (25 VA and 36 VA) selection guide - VA rating | Pin configuration (mm) | | | P1 | S1 | S2 | A 3.2VA | 20 | 10 | 5 | 25 5VA | 25 | 15 | 5 | 25 10VA | 25 | 15 | 27.5 16VA | 30 | 20 | 5 | 30 selection guide - VA rating | Fixed center (mm) | | | Pin configuration (mm) | | | | C1 | C2 | P1 | S1 | S2 | A 25VA | 72.5 | 43.5 | 30 | 20 | 5 | 32.5 36VA | 77.5 | 47.5 | 35 | 20 | 5 | 35 50VA | 82 | 37.5 | 35 | 15 | - | 35 Isolation | Primary to Secondary 5kV AC, Secondary to Secondary 250V AC --- | --- Protection Level | Level 2 Insulation | B Level (130 ° C) pin length x diameter | 5mm x 0.8mm maximum ambient temperature | 3.2VA+60 ° C, 5VA+50 ° C, 10 to 36VA+40 ° C # # # Note: UL506 transformers with 2 x 24V output in accordance with VDE 0550 standard should not be connected in series with secondary devices. ###Recognized ENEC, UL certification # # # Standard EN 61 558 IEC 61558 # # Closed laminated - VC, VCM series34711+$346.322510+$337.288050+$330.3616100+$327.9524200+$326.1455500+$323.73631000+$322.23052000+$320.7248
-
Category: transformerDescription: Power Transformer 2500Vrms 100VA 7Term. Wire Lead Flange Mount45081+$217.872110+$212.188550+$207.8310100+$206.3154200+$205.1787500+$203.66311000+$202.71582000+$201.7685
-
Category: transformerDescription: Installation of 230V AC primary VC/VCM series single or double secondary windings on printed circuit boards, used for series or parallel connection of vacuum epoxy resin molding, compliant with UL94V-O low winding capacitance, low radiation noise, 100% electrical and insulation testing, additional fixing points to ensure board installation fastening (25 VA and 36 VA) Selection guide - VA rating | Pin configuration (mm) | | | | P1 | S1 | S2 | A 3.2VA | 20 | 10 | 5 | 25 5VA | 25 | 15 | 5 | 27.5 16VA | 30 | 20 | 5 | 30 Selection guide - VA rating | Fixed center (mm) | | Pin configuration (mm) | | | | | C1 | C2 | P1 | S1 | S2 | A 25VA | 72.5 | 43.5 | 30 | 20 | 5 | 32.5 36VA | 77.5 | 47.5 | 35 | 20 | 5 | 35 50VA | 82 | 37.5 | 35 | 15 | - | 35 Isolation | Primary to secondary 5kV AC, secondary to secondary 250V Communication --- | --- Protection level | Level 2 insulation | B-level (130 ° C) pin length x diameter | 5mm x 0.8mm Maximum ambient temperature | 3.2VA+60 ° C, 5VA+50 ° C, 10 to 36VA+40 ° C # # # Note: UL506 transformers with 2 x 24V output in accordance with VDE 0550 standard should not be connected in series with secondary equipment. ###Recognized ENEC, UL certification # # # Standard EN 61 558 IEC 61558 # # Closed laminated - VC, VCM series17951+$136.073810+$132.524050+$129.8025100+$128.8559200+$128.1460500+$127.19941000+$126.60782000+$126.0161
-
Category: transformerDescription: 230V Communication primary VC/VCM series single or double secondary windings, used for series or parallel connection of vacuum epoxy resin molding, compliant with UL94V-O low winding capacitance low radiation noise 100% electrical and insulation test additional fixing points to ensure board installation fastening (25 VA and 36 VA) selection guide - VA rating | Pin configuration (mm) | | | P1 | S1 | S2 | A 3.2VA | 20 | 10 | 5 | 25 5VA | 25 | 15 | 5 | 25 10VA | 25 | 15 | 27.5 16VA | 30 | 20 | 5 | 30 selection guide - VA rating | Fixed center (mm) | | | Pin configuration (mm) | | | | C1 | C2 | P1 | S1 | S2 | A 25VA | 72.5 | 43.5 | 30 | 20 | 5 | 32.5 36VA | 77.5 | 47.5 | 35 | 20 | 5 | 35 50VA | 82 | 37.5 | 35 | 15 | - | 35 Isolation | Primary to Secondary 5kV AC, Secondary to Secondary 250V AC --- | --- Protection Level | Level 2 Insulation | B Level (130 ° C) pin length x diameter | 5mm x 0.8mm maximum ambient temperature | 3.2VA+60 ° C, 5VA+50 ° C, 10 to 36VA+40 ° C # # # Note: UL506 transformers with 2 x 24V output in accordance with VDE 0550 standard should not be connected in series with secondary devices. ###Recognized ENEC, UL certification # # # Standard EN 61 558 IEC 61558 # # Closed laminated - VC, VCM series60311+$341.676510+$332.763250+$325.9297100+$323.5528200+$321.7701500+$319.39331000+$317.90772000+$316.4222
-
Category: transformerDescription: 50/60Hz, Linear Transformer Class 289871+$84.867710+$81.1778100+$80.5136250+$79.9970500+$79.18531000+$78.81632500+$78.29975000+$77.8569
-
Category: transformerDescription: XFRM 115/230V 12V 3.33A 40VA PCB84481+$125.205110+$121.938950+$119.4348100+$118.5638200+$117.9105500+$117.03961000+$116.49522000+$115.9508
-
Category: transformerDescription: Power Transformer 4000Vrms 10VA 6Term. PC Pin Thru-Hole69061+$59.851810+$57.2495100+$56.7811250+$56.4168500+$55.84431000+$55.58412500+$55.21975000+$54.9075
-
Category: transformerDescription: CURRENT SENSE TRANSFORMER41655+$15.810250+$15.1346200+$14.7562500+$14.66161000+$14.56702500+$14.45895000+$14.39137500+$14.3238
-
Category: transformerDescription: CURRENT SENSE TRANSFORMER79475+$15.810250+$15.1346200+$14.7562500+$14.66161000+$14.56702500+$14.45895000+$14.39137500+$14.3238
-
Category: transformerDescription: AC CURRENT SENSOR, 16MM HOLE27361+$315.017210+$306.799450+$300.4990100+$298.3076200+$296.6640500+$294.47261000+$293.10302000+$291.7333
-
Category: transformerDescription: Power Transformer 4000Vrms 175VA 8Term. Wire Lead Flange Mount88471+$331.696810+$323.043850+$316.4099100+$314.1024200+$312.3719500+$310.06441000+$308.62222000+$307.1801
-
Category: transformerDescription: Power Transformer 4000Vrms 25VA 12Term. Quick Connect/Solder Lug Flange Mount52671+$79.391410+$75.9396100+$75.3183250+$74.8350500+$74.07561000+$73.73042500+$73.24725000+$72.8330
-
Category: transformerDescription: Power Transformer 4000Vrms 25VA 8Term. Quick Connect/Solder Lug Flange Mount87561+$87.173510+$83.3833100+$82.7011250+$82.1705500+$81.33661000+$80.95762500+$80.42705000+$79.9722
-
Category: transformerDescription: Chassis Mount Power Transformers; TransGlobal Transformer; Primary Voltage: 115V / 230V; Secondary Voltage: 10V CT83851+$216.530110+$210.881450+$206.5508100+$205.0445200+$203.9148500+$202.40851000+$201.46712000+$200.5257
-
Category: transformerDescription: PULSE TRANSFORMER DIGITAL I/O MODULES25351+$1220.043010+$1208.951725+$1203.406150+$1197.8604100+$1192.3148150+$1186.7691250+$1181.2235500+$1175.6778
-
Category: transformerDescription: Audio & Signal Transformers TRANSFORMER65665+$17.567650+$16.8168200+$16.3964500+$16.29131000+$16.18622500+$16.06615000+$15.99107500+$15.9159
-
Category: transformerDescription: RS Pro 2Output through-hole PCB transformer 10-5999, 230V ac primary voltage, 6V ac secondary voltage, 20VA, 50 → 60 Hz operating range44911+$74.854710+$71.6001100+$71.0143250+$70.5586500+$69.84261000+$69.51722500+$69.06165000+$68.6710
-
Category: transformerDescription: Tip/Ring Filter, 2 Function(s), 0.1A, ROHS COMPLIANT PACKAGE-495205+$27.524350+$26.3480200+$25.6893500+$25.52461000+$25.36002500+$25.17185000+$25.05417500+$24.9365
-
Category: transformerDescription: Telecom Transformer 1:1:1 2000VAC 4.8Ω Prim. DCR 2.4Ω Sec. DCR Through Hole8448
-
Category: transformerDescription: VB The PT series 230V AC 50 to 60Hz primary winding, single or double secondary winding, is used for series or parallel connection (for safety compliance reasons, transformers with 2 x 15 and 2 x 18V outputs, 0.35 to 3.2VA, and all transformers with 2 x 24V outputs should not have their secondary windings connected in series, as this means they will not comply with VDE 0550 certification). The VB series (0.35-3.2VA) has inherent short-circuit protection. The PT series (4.5-22VA) is protected by internal PTC equipment with a compact design vacuum epoxy resin molding, achieving UL94-V0 level dual load glass fiber reinforced polyamide wire spools with 100% electrical and insulation testing, high efficiency and low temperature rise, low capacitance between windings, and low radiation noise. Additional fixing holes are provided to ensure low noise between windings at 4.5V. Guidelines for Installing and Tightening the Upper Plate of VA and Higher Transformers (Double Secondary) - VA Rated value | Fixed center (mm) | | Pin configuration (mm) | | | | C1 | C2 | P1 | S1 | S2 | A | Pin size 0.35 | - | - | 15 | 5 | 5 | 15 | 0.6 Ø 0.5 | - | 15 | 5 | 5 | 15 | 0.6 Ø 1.0 | - | - | 20 | 10 | 20 | 0.8 Ø 1.5 | - | 20 | 10 | 5 | 20 | 5 | 20 | 5 | 0.8 Ø 2.3 | - | - | 20 | 10 | 5 | 20 | 0.8 Ø 3.2 | - | - | 20 | 10 | 25 | 0.8 Ø 4.5 | 35 | 28 | 25 | 15 | 5 | 25 | 0.8 Ø 7.5 | 40 | 32 | 25 | 15 | 5 | 27.5 | 0.8 Ø 13 | 47.5 | 37.5 | 30 | 20 | 5 | 30 | 0.8 Ø 22 | 52.5 | 40 | 30 | 10 | 32.5 | 0.8 Ø Isolation | | Primary to Secondary 5kV Secondary to Secondary 250V -------------------- | Protection Level | 2 Insulation: | VB Series PT Series | B Class (130 ° C) A Class (105 ° C) E Class (120 ° C) A Class (105 ° C) Fixed: Strengthen the mechanical fixation of 4.5 to 22VA transformers by using 4 self tapping screws (maximum size 4 x 9.5mm) and fixing holes at the corners of the box. || Maximum ambient temperature | 0.35 to 2.3VA+70 ° C, 3.2VA+50 ° C, 4.5 to 22VA+40 ° C | Selection guide (single secondary) - VA rating | Pin configuration (mm) |61521+$86.688210+$82.9191100+$82.2407250+$81.7130500+$80.88381000+$80.50692500+$79.97925000+$79.5270
-
Category: transformerDescription: Telecom Transformer 1:1 3Ω Prim. DCR 3Ω Sec. DCR 10Term. Gull Wing SMD706410+$6.5100100+$6.1845500+$5.96751000+$5.95672000+$5.91335000+$5.85907500+$5.815610000+$5.7939
-
Category: transformerDescription: 24AWG 300V,250 mm long, all materials UL94-V0 dielectric withstand voltage 4KVrms, working temperature range -40 to+85 º C, large center hole allows 6.3mm plug-in current sensing transformer, low-cost current sensing transformer70721+$55.817410+$52.6148100+$50.2357250+$49.8697500+$49.50371000+$49.09192500+$48.72595000+$48.4971
-
Category: transformerDescription: 24AWG 300V,250 mm in length, all materials UL94-V0 dielectric withstand voltage 4KVrms, working temperature range -40 to+85 º C, large center hole allows 6.3mm plug, current sensing transformer, low-cost current sensing transformer86771+$52.364810+$49.3603100+$47.1284250+$46.7850500+$46.44161000+$46.05532500+$45.71195000+$45.4973
-
Category: transformerDescription: 2.5KV Insulation high saturation current applications include power monitoring, current measurement, and instrumentation. Low cost current induction transformers59195+$30.084250+$28.7986200+$28.0786500+$27.89861000+$27.71862500+$27.51295000+$27.38437500+$27.2558
